Those in the market for Circuitbreaker products such as part number EH2-B050-F2 can count on Instant NSN, where we are dedicated to our customers. Whether you are searching for parts like those with the NSN 5925011370159 or something different, our goal is to help you find what you need with rapid lead times and competitive pricing. As an AS9120B, ISO 9001:2015, and FAA AC 00-56B accredited parts distributor, quality is the cornerstone of our operations. Our expansive inventory of more than 2 billion new, used, obsolete, and hard-to-find components has been sourced from trusted global manufacturers like Siemens Energy And Automation Inc for your benefit. Moreover, countless parts have been subject to varying levels of quality assurance measures to guarantee their fit, form, and function prior to your purchase. With a strict NO CHINA SOURCING pledge, all of our offered products are shipped alongside their applicable qualifying certifications and manufacturing trace documentation to guarantee their caliber.
Note : We Will Not Share Your Information To Any Third Parties.
Take your time to explore our offerings, such as those listed alongside the NSN 5925-01-137-0159, FSC 5925 Circuit Breakers, or the CAGE Code 66842. Once you have reviewed our availability on our online catalog and have discovered parts of interest like those made by the manufacturer Siemens Energy And Automation Inc, you may commence the procurement process through the completion and submission of an RFQ form, as available on our website. While completing this form, be sure to include relevant details such as your desired part quantity and budget parameters so that our dedicated account managers can quickly craft a customized quote for your comparisons within 15 minutes of receiving and reviewing your submission. Instant NSN is here to help you through every stage of the parts procurement process, so do not hesitate to reach out with any questions; our team is available 24/7x365 to assist you.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-137-0159 Item PartTypeName: CIRCUIT BREAKER | 5925 | 011370159 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | S | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
EH2-B050-F2 | 5 | 1 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
ABXD | BUSHING LENGTH | 0.203 INCHES MINIMUM AND 0.235 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 5.984 INCHES MINIMUM AND 6.016 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.984 INCHES MINIMUM AND 3.010 INCHES MAXIMUM |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 5.109 INCHES MINIMUM AND 5.141 INCHES MAXIMUM |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 1.484 INCHES MINIMUM AND 1.516 INCHES MAXIMUM |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.164 INCHES NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 4.578 INCHES MINIMUM AND 4.610 INCHES MAXIMUM |
AEGJ | SWITCH CONTACT ARRANGEMENT | SINGLE POLE,DOUBLE THROW |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 3.984 INCHES MINIMUM AND 4.016 INCHES MAXIMUM |
AKPX | POLE QUANTITY | 2 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 50.0 AMPERES AC ALL LOCATIONS |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC ALL LOCATIONS |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 15000.0 AC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | THERMAL-MAGNETIC ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
CPRZ | AUXILIARY SWITCH FUNCTION AND QUANTITY | 2 ALARM |
CQSM | SWITCH LOCATION AND POSITION DESIGNATION | INTERNAL BETWEEN POLE ONE AND TWO |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS PROOF |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
CRTK | SWITCH TERMINAL TYPE | WIRE LEAD |
CSSX | SWITCH CURRENT RATING AND TYPE IN AMPS | 15.0 AC AND 0.25 DC |
CSWP | SWITCH VOLTAGE RATING AND TYPE IN VOLTS | 240.0 AC AND 250.0 DC |
CWJK | CASE MATERIAL | PLASTIC |
FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
PMLC | PRECIOUS MATERIAL AND LOCATION | TERMINAL AND CONTACT SURFACES SILVER |
PRMT | PRECIOUS MATERIAL | SILVER |
TTQY | TERMINAL TYPE AND QUANTITY | 4 COMPRESSION |